Metallographic analysis is only as good as the specimen under the objective. A perfect microscope imaging a poorly prepared cross-section reports scratches, smearing and edge rounding as microstructure — and the conclusion is wrong with full confidence. This guide walks through the standard preparation sequence from cut to final polish, with the failure modes that most often ruin results at each step.
It applies to ferrous and non-ferrous alloys, welds, coatings and heat-treated parts — the daily workload of any industrial microscopy lab.
Step 1: Sectioning Without Damage
The goal of cutting is a specimen whose subsurface deformation zone is as thin as possible. Abrasive cut-off wheels designed for metallography (not construction discs) with generous coolant flow are the standard; precision saws with diamond or CBN blades for hard or delicate samples. Rule of thumb: if the cut surface burns, discolors or shows chatter marks, the deformation layer beneath is already deeper than your first grinding step can remove.
Step 2: Mounting
- Hot compression mounting (epoxy or phenolic): best flatness and edge retention; the default for routine work.
- Cold mounting (epoxy/acrylic): for heat-sensitive specimens, porous materials or batch work.
- Edge retention: for coating and surface analysis, use epoxy with filler, back-mounting or fixture mounting — edge rounding at the coating interface is the classic artifact that hides the layer you paid to measure.
Step 3: Grinding — Plan the Sequence
Standard sequences move through successively finer SiC papers (typically 120 → 240 → 400 → 600 → 800/1200 grit), removing the damage from the previous step in a fraction of the time of the last. Two rules keep it honest: maintain each step long enough to fully remove prior damage (scratches from the previous grit must be gone before advancing), and clean specimens and hands between steps to avoid dragging coarse grit forward.
Step 4: Polishing
Diamond suspensions (9 µm → 3 µm, sometimes 1 µm) on cloth produce the deformation-free surface etching and imaging require; a final oxide polish (colloidal silica, ~0.05 µm) is standard for EBSD, polarized-light work and soft alloys. Soft metals (aluminium, copper) need aggressive lubrication to avoid smearing; hardened steels tolerate more pressure.
Step 5: Etching — Match the Etchant to the Question
| Goal | Common etchant | Notes |
|---|---|---|
| General microstructure, carbon steels | Nital (2–5%) | Fast, contrast for ferrite/pearlite boundaries |
| Prior austenite grain boundaries | Picral variants / temper etch | Requires control; structure-sensitive |
| Stainless steels, Ni alloys | Glyceregia / Kalling’s | Fume handling per SDS |
| Aluminium alloys | Keller’s | Short immersion; over-etching removes detail |
Whenever possible, prepare at least one unetched specimen — inclusions, porosity and cracks are often more visible unetched.
Step 6: Microscope Setup for Repeatable Imaging
Consistent illumination (Köhler alignment), calibrated magnification with a stage micrometer, and documented exposure settings turn images into evidence. For quantitative work — grain size, phase fractions, coating thickness — fix the imaging parameters per material family and record them with the specimen ID. Polarized light and DIC contrast earn their place on non-etched or anisotropic samples where brightfield flattens everything.
Frequently Asked Questions
What is the most common cause of bad metallographic images?
Carried-over grinding damage: advancing to the next grit before the previous scratch pattern is fully removed. The subsurface deformation then looks like microstructure under the microscope.
How do I keep the coating edge sharp for thickness measurement?
Use mounting strategies for edge retention — epoxy with filler, back-mounting or fixtures — and avoid excessive polishing pressure at the edge.
Which etchant should I start with for steel?
2–5% nital covers most carbon and low-alloy steel work. Specialty questions (prior austenite grains, sensitization) need dedicated etchants.
Do I always need to etch?
No. Inclusions, cracks and porosity are frequently best assessed on an unetched, well-polished surface. Etch to reveal phase structure, not by default.
How fine should the final polish be?
1 µm diamond is sufficient for routine brightfield work; 0.05 µm oxide polish is standard for EBSD, polarized light and soft alloys.